Motor Configuration Settings
AB CD
No Signal Positive
Half Wave
Negative
Half Wave
Full
Wave
Cool
S3-1 OFF ON OFF ON
S3-2 OFF OFF ON ON
Adjust
S3-3 OFF ON OFF ON
S3-4 OFF OFF ON ON
Delay
S4-1 OFF ON OFF ON
S4-2 OFF OFF ON ON
Heat
S4-3 OFF ON OFF ON
S4-4 OFF ON ON ON
OPTION SWITCH SETTING -
MOTOR OPTIMIZATION
Amana/Goodman/Trane/Lennox/Thermo Pride – The motor
configuration DIP switches S3 and S4 must be set to match
settings of the original furnace settings for proper motor function.
To set the new board for the motor function, the DIP switches
must be set to match the settings of the board being replace.
IMPORTANT: Be sure to use proper switches for new
board settings. Switch locations on old board may not be
the same location as on the new board.
DELAY
A
B
C
D
A
B
C
D
A
B
C
D
COOL HEAT ADJ
E45
E43
E46
E44
York – The existing board has four shunt jumper banks to set
motor function configuration. The four jumper banks are des-
ignated DELAY (E45), COOL (E43), HEAT (E46), ADJ. (E44).
Each jumper bank has four pair of pins to have jumper installed
to determine the type of voltage to the motor. These pin pairs
are A (no signal) B ( positive Half-wave rectified), C (negative
Half-wave rectified), D (Full-wave unrectified).
On the new board, the motor functions must be duplicated on
DIP switched S3 and S4 per the following table.
NORMAL OPERATION – HEAT ON
When the thermostat calls for heat the module verifies the
pressure switches are open and energizes the inducer
(high speed) and optional humidifier contacts. When the low
pressure switch contacts close a 15 second pre-purge begins.
After 15 seconds the inducer switches to low speed and the
120 VAC ignitor is energized. The ignitor warms up for 17
seconds and the gas valve is energized on low fire. Flame
must be detected within 4 seconds. If flame is detected, a 45
second heat, fan on time delay begins. This allows the heat
exchanger to warm up before energizing the circulator on low
speed and (optional) Electronic Air Cleaner contact. When the
thermostat (or module) initiates second stage the inducer is
energized at high speed.
This closes the second stage inducer pressure switch then
energizes the second stage on the gas valve and then the high
heat circulator speed.
NORMAL OPERATION – HEAT OFF
When the thermostat satisfies for second stage, the control
will switch high speed inducer and high fire gas valve to low
speed inducer and low fire gas valve. After the 30 second high
heat fan delay the circulator will drop to low speed. When the
thermostat satisfies for first stage the gas valve de-energizes
and the inducer will run low speed for a 15 second post-purge.
The circulator runs until the heat off delay ends.
Note: If the module is configured for a single stage thermostat
and running on second stage when the call for heat ends, the
circulator will drop to low speed after 30 seconds and continue
until the heat off delay ends.
COOL MODE
In a typical system, a call for cool is initiated by closing Y
and G. This energizes the compressor and the electronic air
cleaner (optional). The electronic air cleaner and the G and (Y
or YLO outputs to the Circulator motor will energize after the 5
second cool on delay period. After the thermostat is satisfied,
the compressor is de-energized and the control starts a 60
second cool circulator speed off delay. After 60 seconds the
circulator is de-energized.
MANUAL FAN ON MODE
If the thermostat fan switch is moved to the “ON” position, the
electronic air cleaner (optional) and the G circulator output to
the circulator motor will be energized. When the fan switch is
returned to the AUTO position, the G circulator output and the
electronic air cleaner are de-energized.
SW4
1 2 3 4
ON
OFF
SW3
1 2 3 4
ON
OFF
Switch Position
50V51-843
(New Board)
SW4
5 6 7 8
ON
OFF
SW3
1 2 3 4
ON
OFF
Existing 50V51
or 50V61
INTEGRATED
FURNACE CONTROLS
21V51U-843
OPERATION
www.white-rodgers.com
186
TECHNICAL HELP