1F82-0261/1F89-0211 CONFIGURATION
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.
To enter the menu: Set your thermostat to OFF and press the
and buttons simultaneously. The display will show the
first item in the configuration menu. Press RUN/HOLD to change to the next menu item or press TIME to go backwards to the
previous item in the menu. To exit the menu and return to the program operation, press PRGM. If no keys are pressed within
fifteen minutes, the thermostat will revert to normal operation.
1F82-0261 INSTALLER/CONFIGURATION MENU
1F89-0211 INSTALLER/CONFIGURATION MENU
CONFIGURATION MENU
Menu
Reference
Number
Heat
Pump
Single
Stage
Press
Key
Displayed
(Factory
Default)
Press
or
to select from listed
options COMMENTS
111
and
HP SS Select Heat Pump (HP, 1 compressor) or Single Stage (SS)
222RUN/HOLD* CS (OFF) On Select Cool Savings Feature On or OFF
RUN/HOLD* CS (3) 1, 2, 3, 4, 5, 6 If CS selected On, selects Cool Savings value
333RUN/HOLD* E (On) OFF Select Energy Management Recovery On or OFF
44 RUN/HOLD* CR HE-PU
(FA)
SL Select Adjustable Anticipation, cycle rate, Heat Pump, Heat and
Cool
4 RUN/HOLD* CR Heat
(FA)
SL Select Adjustable Anticipation, cycle rate,
Heat Single Stage
55 RUN/HOLD* CR Aux
(FA)
SL Select Adjustable Anticipation, cycle rate,
Heat Pump Aux Stage
5 RUN/HOLD* CR Cool
(FA)
SL Select Adjustable Anticipation, cycle rate, Cool Single Stage
666RUN/HOLD* CL (OFF) On Select Compressor lockout OFF or On
777RUN/HOLD* L (On) OFF Select Display Light On or OFF
888RUN/HOLD* Temp
(0 HI)
4 LO to
4 HI
Select temperature display adjustment higher or lower
999RUN/HOLD*
o
F
o
C Select
o
F /
o
C Display (temperature units in Fahrenheit or Celsius)
10 10 RUN/HOLD* FH (On) OFF Select fast second stage On or OFF
11 11 10 RUN/HOLD* Change Filter
(OFF)
On Select filter replacement indicator OFF or On
RUN/HOLD* Change Filter
(200 h)
25 to 1975 If Change Filter selected On, selects time interval for Change Filter
Indicator. (in 25 hour increments)
12 RUN/HOLD* Returns to normal operation
*Press RUN/HOLD to advance to next item or TIME to move backwards to previous item
CONFIGURATION MENU
Menu
Reference
Number
Press
Key
Displayed
(Factory
Default)
Press
or
to select from listed
options COMMENTS
1
and
CS (OFF) On Select Cool Savings Feature On or OFF
and
CS (3) 1, 2, 3, 4, 5, 6 If CS selected On, selects Cool Savings value
2
and
CR HE-PU
(FA)
SL Select Adjustable Anticipation, cycle rate, Heat Pump, Heat and Cool
3
and
CR Aux (FA) SL Select Adjustable Anticipation, cycle rate,
Heat Pump Aux Stage
4
and
CL (OFF) On Select Compressor lockout OFF or On
5
and
L (On) OFF Select Display Light On or OFF
6
and
Temp
(0 HI)
4 LO to
4 HI
Select temperature display adjustment higher or lower
7
and
o
F
o
C Select
o
F /
o
C Display (temperature units in Fahrenheit or Celsius)
8
and
FH (On) OFF Select fast second stage On or OFF
9
and
Change Filter
(OFF)
On Select filter replacement indicator OFF or On
and
Change Filter
(200 h)
25 to 1975 If Change Filter selected On, selects time interval for Change Filter Indicator.
(in 25 hour increments)
10
and
Returns to normal operation