CONFIGURATION1F95-0671
CONFIGURATION MENU
Menu
Ref. HP SS
Press
Button
Displayed
Factory (Default)
Press or
to select from
listed options COMMENTS
13 12 12 MENU (On) b OFF May select Beeper OFF to stop audible
key feedback
14 13 13 MENU (7) P 3, 0 Defaults 7-day programming (P7) but non-
programmable (0) or 5/1/1 programming (P3)
is available on most models.
15 14 14 MENU (4) PS 2 Selects Program periods per day:
4 = Morn, Day, Eve, Night
2 = Day, Night
16 15 15 MENU (On) Heat AS OFF Automatic Schedule for heat mode
17 16 16 MENU (On) Cool AS OFF Automatic Schedule for cool mode
18 17 MENU (On) Heat FA OFF Fast Heat option may be disabled by
selecting OFF. NA to SS or HP1 config.
19 18 MENU (On) Cool FA OFF Fast Cool option may be disabled by
selecting OFF. NA to SS or HP1 config.
20 19 17 MENU Remote (OFF) On Selects Remote Sensor On/OFF
MENU Remote
(In)
Outdoor Selects Remote Sensor to outdoor
NA is Remote Sensor OFF
MENU Indoor Loc
(On)
OFF Selects Local Sensor (in thermostat) to OFF. N/A if Remote is
selected to Outdoor
21 20 18 MENU (On) dS Off Selects Automatic Daylight Saving Time option
22 21 19 MENU (OFF)
Keypad Lockout
L, P, Limit Selects one of 3 Keypad Lockout configurations
L - Total Keypad Lockout
P - Partial Keypad Lockout
(Up and Keys still work)
Limit - Limited Temperature Range
MENU (000)
Keypad Lockout
1-999 Selects personal lockout code. 000 is NOT A VALID CODE.
23 22 20 MENU (99) L Heat L 62 to L 98 Select Limited HEAT Range Temperature
24 23 21 MENU (45) L Cool L 46 to L 82 Select Limited COOL Range Temperature
25 24 MENU CO
(05)
06-50 Selects outdoor Compressor OFF temperature (Balance Point
temperature). 05 disables feature. Outdoor Remote required
MENU (dF) EA Selects between dF (dual Fuel) or EA (Electric Aux) only avail-
able if CO is greater than 05
MENU (60) Cd Selects Compressor delay OFF time in seconds
(only if dF is selected)
26 25 MENU AO
(80)
Selects AO (Auxiliary OFF) temperature. Feature disabled if 80
is selected. Outdoor Remote required
27 26 22 MENU (OFF) Change Filter On Selects Filter Change-out Indicator On or OFF.
MENU Change Filter (200 h) 25-1975 h Change Filter time in 25 hour increments. This menu only appears
if On is selected in above.
28 27 23 MENU (OFF)
Change UV Lamp
On Selects UV Lamp
Timer: On/OFF
MENU (350)
Change UV Lamp
25-1975 Selects number of Days between
changing UV Lamp
29 28 24 MENU (o) Cool On Heat On (b) Selects operation of the reversing valve terminal (O/B) output as
an O or B terminal
30 29 27 MENU Returns to Normal Operation