Heat Pump 1
(HP1)
Single
Compressor
Heat Pump
24 Volt
(Hot)
Blower/
Circulator
Fan Energized
on Call for
Heat/Cool
or Fan,
Note: Set
Elect/Gas
switch for
Emergency
Mode Heat Type
24 Volt
(Common)
Optional
Connection
System
*C
CLASS II
TRANSFORMER
HOT
24VAC
24VAC
COOL
HEAT
NEUTRAL
120VAC
Fault
Indicator
for Heat
Pump
Systems
with
Malfunction
Switch
L
R
E/W1
Y2
G
Emergency
Mode
1st Stage
Heat Mode-
1st Stage
Cool Mode-
1st Stage
(Compressor 1)
Y1
W2
Energized
in Cool
Mode
(Change-
over Valve)
O
Energized
in Heat, Off,
Emergency
Mode
(Change-
over Valve)
B
Heat Mode-
2nd Stage
Cool Mode-
2nd Stage
(Compressor 2)
Heat Pump 2
(HP2)
Two
Compressor
or Two Speed
Compressor
No Output
Heat
Mode
2nd Stage.
Emergency
Mode 2nd
Stage
Heat
Mode
3rd Stage.
Emergency
Mode 2nd
Stage
CUT AND
TAPE OFF
TWO COMMONS MUST
BE JUMPERED TOGETHER
HOT
NEUTRAL
120VAC
Multi-Stage
(MS2)
24 Volt
(Hot)
Blower/
Circulator
Fan Energized
on Call for
Cool or Fan,
Energized on
Call for Heat if
Elect/Gas
Switch Set to
Electric
24 Volt
(Common)
Optional
Connection
System
*C
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Fault
Indicator
for Heat
Pump
Systems
with
Malfunction
Switch
L
R
E/W1
Y2
G
Heat
Mode
1st Stage
Cool Mode
1st Stage
(Compressor 1)
Y1
Heat
Mode
2nd Stage
W2
Energized
in Cool
Mode
(Change-
over Valve
or Damper)
O
Energized
in Heat, Off
Mode
(Change-
over Valve
or Damper)
B
Cool Mode
2nd Stage
(Compressor 2)
Figure 5 – Multi-Stage (No Heat Pump) Terminal Outputs
Heat Pump 1
(HP1)
Single
Compressor
Heat Pump
24 Volt
(Hot)
Blower/
Circulator
Fan Energized
on Call for
Heat/Cool
or Fan,
Note: Set
Elect/Gas
switch for
Emergency
Mode Heat Type
24 Volt
(Common)
Optional
Connection
System
*C
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Fault
Indicator
for Heat
Pump
Systems
with
Malfunction
Switch
L
R
E/W1
Y2
G
Emergency
Mode
1st Stage
Heat Mode-
1st Stage
Cool Mode-
1st Stage
(Compressor 1)
Y1
W2
Energized
in Cool
Mode
(Change-
over Valve)
O
Energized
in Heat, Off,
Emergency
Mode
(Change-
over Valve)
B
Heat Mode-
2nd Stage
Cool Mode-
2nd Stage
(Compressor 2)
Heat Pump 2
(HP2)
Two
Compressor
or Two Speed
Compressor
No Output
Heat
Mode
2nd Stage.
Emergency
Mode 2nd
Stage
Heat
Mode
3rd Stage.
Emergency
Mode 2nd
Stage
Figure 6 – Heat Pump Terminal Outputs
Figure 7 – Heat Pump Terminal Outputs - Two Transformer with no Safety Circuits
WIRING CONNECTIONS
* The RC/PS switch shown in Figure 1 configures the thermostat for Hardwire or Power Stealing.
The factory setting is RC (Hardwire) and requires a Common connection from the system transformer to the "C" terminal on
the thermostat. If no common wire is available for the thermostat "C" terminal, move the RC/PS switch to PS (Power Steal-
ing). NOTE: If set to PS (Power Stealing), the thermostat "C" terminal must not have a wire connected.
Single Stage
(SS1)
24 Volt
(Hot)
Blower/
Circulator
Fan Energized
on Call for
Cool or Fan,
Energized on
Call for Heat if
Elect/Gas
Switch Set to
Electric
No Output
24 Volt
(Common)
Optional
Connection
System
*C
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Fault
Indicator
for Heat
Pump
Systems
with
Malfunction
Switch
L
R
E/W1
Y2
G
Heat
Mode
1st Stage
(Heater)
Cool Mode
1st Stage
(Compressor)
Y1
No Output
W2
Energized
in Cool
Mode
(Change-
over Valve
or Damper)
O
Energized
in Heat, Off
Mode
(Change-
over Valve
or Damper)
B
Figure 4 – Single Stage (No Heat Pump) Terminal Outputs