Corrective Action
Antenna wire must be installed into the wall
Thermostat and sensor must be at least 5 feet above the
floor
Relocate thermostat or sensor
Relocate thermostat or sensor away from obstacle
If thermostat is indicating that it is receiving, the remote is
transmitting. If you wish to have the remote sensor
display show Temperature and Transmitting icon, change
the User Configuration Menu, item 4 from OFF to On
TROUBLESHOOTING
White-Rodgers is a division
of Emerson Electric Co.
The Emerson logo is a
trademark and service mark
of Emerson Electric Co.
www.white-rodgers.com
www.emersonclimate.com
HOMEOWNER HELP LINE: 1-800-284-2925
Symptom
Poor Communication
between sensor and
thermostat
Remote sensor display
shows only PWR and On.
Transmitting icon does not
appear. In Learn mode,
Transmitting icon and
Learn icon do not appear
Possible Cause
Antenna were installed improperly
Thermostat and/or sensor not at proper
height
Thermostat or sensor may be too close to a
wireless device or noise producing device
Thermostat or sensor may have obstacles
in wall
Remote sensor is configured to have
display OFF
Communication Diagnostic
The thermostat will monitor the integrity of the communication between the thermostat, receiver and wireless remote sensors. When the
thermostat detects a potential communication problem, the LED will flash to indicate a failure code. The LED will flash at 1/2 second On/
Off with a 2 second pause. If more than one error occurs, the highest priority warning will be shown until it is resolved. The indication of
the codes is listed below in the highest priority order.
Possible Cause
Power Mode Switch S7 set to RC and common wire not
connected to C terminal.
Receiver antenna not positioned properly
Poor remote sensor location or orientation
Noisy environment
Radio interferring signal
To prevent this error indication press and hold RUN for 4
seconds to override. Override will be cleared on power-up.
Receiver not programmed (learned) to sensor
Other remote sensor operating on same RF frequency
channel
Receiver installed improperly
Receiver module inoperative
Remote sensor battery dead
Remote sensor has been moved or removed
Remote sensor battery dead
Remote sensor has been moved or removed
Local sensor temperature sensing circuit malfunction.
Code
(Flashes)
1
2
3
4
5
6
7
Indication
24 VAC lost or not present (receiver will turn off and stop
communication with wireless remote sensor)
The receiver detected an invalid packet that fails CRC
check
The receiver detected abnormal false tripping
Receiver detected unidentified packet that passes CRC
check
Thermostat failed to communicate with receiver module
Indoor remote sensor not responding (Indoor sensor is
enabled and thermostat has not received update for over
30 minutes) thermostat will display Fault and antenna icon
Outdoor remote sensor not responding (Outdoor sensor is
enabled and thermostat has not received update for over
30 minutes) thermostat will display Fault and antenna icon
Local sensor faulty