Printed in U.S.A.
PART NO. 37-4740B
Replaces 37-4740A
9307
1F91-71
Multi-stage Electronic Digital Thermostat
PRECAUTIONS
Operator: Save these instructions for future use!
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
This wall-mounted, low voltage thermostat maintains
room temperature by controlling the operation of multi-
stage systems. Use this thermostat for applications
requiring up to three stages of heat and up to two stages
of cool. Indicator lights show the system status. The user
may program up to four time/temperature settings per 24
hour period. The thermostat stores settings for a five-day
(weekday) program and a two-day (weekend) program.
The thermostat will store both heating and cooling pro-
grams simultaneously. A 9 volt Energizer
®
battery will
maintain the stored program for approximately one week,
if incoming power should fail. If power failure is extensive
and the program is lost, after power restoration, the
thermostat will automatically maintain a factory
preprogrammed heating temperature of 64°F or a cooling
temperature of 82°F.
INSTALLATION INSTRUCTIONS
WHITE-RODGERS
W H I T E - R O D G E R S
DIGITAL COMFORT SET
II
If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installa-
tion is complete.
Do not use on circuits exceeding specified volt-
age. Higher voltage will damage control and
could cause shock or fire hazard.
Do not short out terminals on gas valve or pri-
mary control to test. Short or incorrect wiring
will burn out thermostat and could cause per-
sonal injury and/or property damage.
WARNING
!
CAUTION
!
CONTENTS
Description .......................................................... 1
Precautions ......................................................... 1
Specifications ......................................................2
Installation...........................................................2
New Installation
Select Thermostat Location
Route Wires to Location
Replacement Installation
Remove Old Thermostat
Attach Subbase to Wall
Attach Thermostat to Subbase
Operation ............................................................6
System Configuration
Set Option Switches
Check Thermostat Operation
Fan Operation
Heating System
Cooling System
Troubleshooting
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - WHITE-RODGERS

Printed in U.S.A.PART NO. 37-4740BReplaces 37-4740A93071F91-71 Multi-stage Electronic Digital ThermostatPRECAUTIONSOperator: Save these instructions

Pagina 2 - NEW INSTALLATION

2SPECIFICATIONSINSTALLATIONTHIS CONTROL IS DESIGNED FOR USE WHERE BOTH SIDES OF THE TRANSFORMER ARE PRESENTTO THE THERMOSTAT (both the hot and common

Pagina 3 - REPLACEMENT INSTALLATION

3REPLACEMENT INSTALLATIONREMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installa-tion is complete. Verify power is off with

Pagina 4 - Figure 3. Subbase

42. Connect wires beneath terminal screws on subbaseusing wiring schematic (see figs. 3 through 6).3. Place subbase over hole in wall and mark mounti

Pagina 5 - THERMOSTAT

5IF SAFETY CIRCUITS ARE IN ONLY ONE OF THESYSTEMS, REMOVE THE TRANSFORMER OF THESYSTEM WITH NO SAFETY CIRCUITS.NOTEHeatRelayStage 2CompressorContactor

Pagina 6 - OPERATION

6ATTACH THERMOSTAT TO SUBBASEIT IS RECOMMENDED THAT YOU SET OPTIONSWITCHES TO DESIRED POSITION BEFORE ATTACH-ING ON SUBBASE (see OPERATION). IT IS A

Pagina 7 - LOCKOUT BYPASS OPTION

7CHECK THERMOSTAT OPERATIONFAN OPERATION1. Turn on power to the system. If the heat source hasa standing pilot, be sure to light it.2. Press FANSWITC

Pagina 8 - WARRANTY INFORMATION

If you need further information about this product, please write toWhite-Rodgers Division, Emerson Electric Co.9797 Reavis RoadSt. Louis, MO 63123-53