White-rodgers 1F97W-51 Manual de usuario

Busca en linea o descarga Manual de usuario para Panel De Control White-rodgers 1F97W-51. White Rodgers 1F97W-51 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
OPERATION GUIDE
7-Day Programmable Electronic
Digital Thermostat
1F97W-51
WHITE-RODGERS
Operator: Save this booklet for future use!
Vista de pagina 0
1 2 3 4 5 6 ... 39 40

Indice de contenidos

Pagina 1 - 1F97W-51

OPERATION GUIDE7-Day Programmable ElectronicDigital Thermostat1F97W-51WHITE-RODGERSOperator: Save this booklet for future use!

Pagina 2

10The Thermostat Buttons7Sets the system mode (HEATing, OFF, orCOOLing).8Selects fan operation (see #6, above). Thisbutton is also used to program the

Pagina 3

111011121314 15161718978FAN AUTOVIEWPRGMRUNPRGMFANON - AUTOHOLDCOPYVIEWTEMPSETCLOCKADVDAYSYSTEMHEAT - OFF - COOL TIMEFWDTIMEBACK17(Blue arrow) Lowers

Pagina 4

12OPERATING FEATURESNow that you are familiar with the thermostatdisplay and buttons, read the following informa-tion to learn about the many features

Pagina 5 - OPERATING YOUR THERMOSTAT

13CAUTION!• HOLD TEMPERATURE — The thermostatcan hold any temperature within its rangefor an indefinite period, without reverting tothe program. Press

Pagina 6 - PARTS OF THE THERMOSTAT

14Whenever adjusting anticipation, increaseor decrease the displayed number by onlyone or two digits, then let the system run fora while to see if the

Pagina 7

15The word BATTERY will be displayed con-tinuously (non-flashing) when 24 VAC poweris not being supplied to the thermostat and thethermostat is operat

Pagina 8

16Now you are ready to program your thermostat.This section will help you plan your thermostat’sprogram to meet your needs.For maximum comfort and eff

Pagina 9

173a. What time do the building occupants reacha minimum activity level (limited personnelin building)?b. What temperature should the building be atth

Pagina 10

18However, you may use the same heatingand cooling temperatures for consecutivetime periods. Also keep in mind that, for anygiven day, you can only pr

Pagina 11 - (40°F or 4°C minimum)

19TemperatureDesignationFactoryPreprogrammedTemperatureYourSelectedTemperatures*HEAT AHEAT BHEAT CHEAT D70707064COOL ACOOL BCOOL CCOOL D78827878* You

Pagina 12 - OPERATING FEATURES

2About Your New Thermostat . . .Your new White-Rodgers Digital Thermostat uses the technology of a solid-state microcomputerto provide precise time/te

Pagina 13 - °F, repeat the process

20Period 1 Period 2 Period 3 Period 4TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp.MondayTuesdayWednesday

Pagina 14

21Period 1 Period 2 Period 3 Period 4TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp.MondayTuesdayWednesday

Pagina 15 - PROGRAMMING

22ENTERING YOUR PROGRAMFollow these steps to enter the heating/coolingprogram you have selected.We recommend that you remove the thermostatfrom the wa

Pagina 16

237. Press RUNPRGM once. The display will show thecorrect time and room temperature alter-nately.Select Heating and Cooling TemperaturesDuring program

Pagina 17

24(if you only want to program temperatures forHEAT A and HEAT B, skip to step 7).6. Repeat steps 4 and 5 to select HEAT C andHEAT D temperature setti

Pagina 18

25HEAT A, B, C, or D temperature for heating/cooling period 1.EXAMPLE: 3. To change the displayed start time to yourselected start time for Monday’s p

Pagina 19

26The thermostat has a built-in COPY feature.This feature automatically copies the heatingand cooling programs you select for Mondayinto Tuesday’s thr

Pagina 20 - Heating/Cooling Schedule Plan

27Program Cooling TemperaturesIf outside temperature is below 50°F, werecommend that you remove the ther-mostat from the wall before proceedingwith th

Pagina 21

28run continuously during this period, pressFANON - AUTO until PRG FAN is displayed.5. Repeat step 4 for Monday’s heating coolingperiods 3 and 4.6. Us

Pagina 22

292. Press ADVDAY until the day you want to copyfrom is displayed. If you have not com-pleted programming for this day, do sobefore proceeding.3. Pres

Pagina 23 - HEAT - OFF - COOL

3Operator: Save thisbooklet for future use!ENTERING YOUR PROGRAMSet Current Time and DaySelect Heating and Cooling TemperaturesProgram Heating/Cooling

Pagina 24

303. Press ADVDAY once to advance to Tuesday.4. Press and hold VIEWPRGM to view heating/coolingperiods and heating temperatures for Tues-day.5. Repeat

Pagina 25

311. How can I permanently change a part ofmy program?Press VIEWPRGM and ADVDAY until you reach thetime/temperature schedule you want. Thenpress TIMEF

Pagina 26

32press RUNPRGM to start the normal programfunction. See PROGRAMMING YOURTHERMOSTAT.4. What happens if the electricity goes offor is manually shut off

Pagina 27 - ON - AUTO

33and the display is blank or frozen, staticdischarge is probably the cause.During periods of low humidity (especiallyduring cold weather), you may fe

Pagina 28

348. The thermostat beeps every few min-utes. What does this mean?The thermostat will beep every five minuteswhen the batteries are low and need repla

Pagina 29

35If the outside temperature is below 50°F,DO NOT use the button to move thetemperature below the setpoint tempera-ture. Property damage may result

Pagina 30

3612. Why does the blower fan keep runningafter the system has turned off?• You have programmed the fan to runcontinuously during this period. See PRO

Pagina 31 - QUESTIONS AND ANSWERS

3715. I live in an area where daylight savingstime is observed. How do I change thethermostat clock twice a year withoutaffecting thermostat programmi

Pagina 32

38NOTES

Pagina 33

39NOTES

Pagina 34

4• Seven independent day programming• Simultaneous heat and cool program storage• Four separate time/temperature settings per24-hour period• Computed

Pagina 35

Part No. 37-5094BReplaces 37-5094A9531If you need further information on programming or operation, write to:White-Rodgers Division, Emerson Electric C

Pagina 36

5OPERATING YOUR THERMOSTATBefore you begin programming your thermo-stat, you should be familiar with its featuresand with the display and the location

Pagina 37

6PARTS OF THE THERMOSTATThe Back of The Thermostat BodyTurn the thermostat body over. On the back arethe 3 “AA” Energizer® alkaline batteries.The “AA”

Pagina 38

7Use SYSTEMHEAT - OFF - COOL to turn thermostat OFF be-fore removing thermostat from the wallto replace the batteries.Other than and , the buttons

Pagina 39

8The Display1Continuously displays system mode (HEAT,OFF, COOL, HOLD). During programming,the day of the week is displayed (MON,TUE, WED, etc.).2Alter

Pagina 40 - Replaces 37-5094A

91 2 3466AB2354FAN AUTO FAN ON BATTERYFAN AUTOVIEWPRGMRUNPRGMFANON - AUTOHOLDCOPYVIEWTEMPSETCLOCKADVDAYSYSTEMHEAT - OFF - COOLTIMEFWDTIMEBACK

Comentarios a estos manuales