Printed in U.S.A.
PART NO. 37-5456A
Replaces 37-1794 &
37-9517
9510
TYPE 668
Intermittent Ignition* – Non Recycling
OIL BURNER CONTROL
With Series 956 Flame Detector
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300, Fax (314) 577-1517
9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625
DESCRIPTION
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
The proper Location and Mounting of the primary oil
burner control panel on the burner and the flame detector
with respect to the oil flame shall be determined by the
furnace, boiler, or burner manufacturer.
If this control, supplied as part of a furnace, boiler or
burner, is wired to the equipment or if the manufacturer
of such equipment provides instructions for wiring this
* Formerly called constant ignition.
SPECIFICATIONS
Electrical Data
Input voltage: 668 120V. AC, 60Hz.
668H 220V. AC, 50/60Hz.
Maximum Load Current:
Oil Burner Motor (Orange Wire):
10 Amps F.L. 60 Amps L.R.
Ignition Transformer:
360VA (3.0 Amps)
Relay Voltage: 668 24 Volts AC, 60Hz.
668H 24 Volts AC, 50/60Hz
Room Thermostat:
Set adjustable heat anticipator at 0.4 Amps. For fixed
anticipation thermostats, use 0.35 to 0.45 Amp.
heater.
Safety Timing:
668, 668H-401 to 499: 45 seconds
668, 668H-501 to 599: 30 seconds
668, 668H-601 to 699: 15 seconds
INSTALLATION AND WIRING
control, then follow his recommendations. If no special
wiring instructions are given, then follow the electrical
connections shown on this diagram for a simple system.
For more complicated systems, especially for hot water
heating, consult the manufacturer of the heating plant for
full details of the desired sequence of control operation.
To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.
If in doubt about whether your wiring is millivolt, line, or
low voltage, have it inspected by a qualified heating and
air conditioning contractor, electrician, or someone famil-
iar with basic electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
CAUTION
!
PRECAUTIONS
WARNING
!
WHITE-RODGERS
The type 668 Oil Burner Control provides safe operation
of oil burners on heating plants where ignition during the
entire burner cycle is desired.
The 668 is used with the 956 Flame Detector
Vista de pagina 0
1 2 3 4 5 6

Indice de contenidos

Pagina 1 - WHITE-RODGERS

Printed in U.S.A.PART NO. 37-5456AReplaces 37-1794 &37-95179510TYPE 668Intermittent Ignition* – Non RecyclingOIL BURNER CONTROLWith Series 956 Fla

Pagina 2 - External Line Voltage Wiring

2Possible Cause of CorrectionTroubleOpen circuit in Cell Replace Cell (or Cell Assembly)of 956 Flame Detector. Do notdisturb position of bracket orsoc

Pagina 3 - TESTING CONT

34. If safety lockout problem is of an occasional naturethe following additional check may be made toinsure that flame detector location is not a marg

Pagina 4

WHITE-RODGERSImprimé aux États-UnisNo de pièce 37-5456ARemplace : 37-1794 &37-95179510Utilisateur : conservez ces instructions pour vous y référer

Pagina 5 - AVERTISSEMENT

2Une fois l’installation complétée, il est recommandé de mettrele système à l’essai pour s’assurer de son bon fonctionnement.1. Ouvrez l’interrupteur

Pagina 6 - ESSAIS (SUITE)

3ESSAIS (SUITE)d. Si la résistance du détecteur dépasse 1000 ohms, ilest possible que celui-ci ne détecte pas très bien laflamme du brûleur. Vérifiez

Comentarios a estos manuales

Sin comentarios

Empire Comfort Systems OLP42FP72S-2 manuals

Owner’s manuals and user’s guides for Fireplaces Empire Comfort Systems OLP42FP72S-2.
We providing 1 pdf manuals Empire Comfort Systems OLP42FP72S-2 for download free by document types: Owner's Manual






More products and manuals for Fireplaces Empire Comfort Systems

Models Document Type
DVCC32LP Owner's Manual   Empire Comfort Systems DVCC32LP Owner`s manual, 52 pages
9)0L(N Owner's Manual   Empire Comfort Systems 9)0L(N Owner`s manual, 24 pages
VFLL48SP(3 Owner's Manual   Empire Comfort Systems VFLL48SP(3 Owner`s manual, 44 pages
VFD36FB2ML-1 Owner's Manual   Empire Comfort Systems VFD36FB2ML-1 Owner`s manual, 20 pages
DVL33IN33N-1 Owner's Manual   Empire Comfort Systems DVL33IN33N-1 Owner`s manual, 36 pages
DVP30CA30BN-2 Owner's Manual   Empire Comfort Systems DVP30CA30BN-2 Owner`s manual, 24 pages
VFD32FB0F-2 Owner's Manual   Empire Comfort Systems VFD32FB0F-2 Owner`s manual, 23 pages
VFLL48FP Owner's Manual   Empire Comfort Systems VFLL48FP Owner`s manual, 56 pages
DVD36FP34N-1 Owner's Manual   Empire Comfort Systems DVD36FP34N-1 Owner`s manual, 44 pages
ONR-30-1 Owner's Manual   Empire Comfort Systems ONR-30-1 Owner`s manual, 24 pages
VFSR-16-4 User Manual   The Breckenridge Series - Percy Guidry Companies, 8 pages
BP)-1 Owner's Manual   Empire Comfort Systems BP)-1 Owner`s manual, 56 pages
CP Owner's Manual    Empire Comfort Systems CP Owner`s manual, 28 pages
VFD32FB0L-3 Owner's Manual   Empire Comfort Systems VFD32FB0L-3 Owner`s manual, 24 pages
VSR-30-1 User Manual   The Breckenridge Series, 8 pages
VFP36PP32EP-2 Owner's Manual   Empire Comfort Systems VFP36PP32EP-2 Owner`s manual, 40 pages
VFIL Series Owner's Manual   Empire Comfort Systems VFIL Series Owner`s manual, 16 pages
VFS42FB0F-4 Owner's Manual   Empire Comfort Systems VFS42FB0F-4 Owner`s manual, 16 pages
BMHK-24N-1 Owner's Manual   Empire Comfort Systems BMHK-24N-1 Owner`s manual, 48 pages
OP42FB2MF-2 Owner's Manual   Empire Comfort Systems OP42FB2MF-2 Owner`s manual, 16 pages