5 minutes between cooling cycles. The
following may cause a time delay in COOL:
a) Return of power after a power outage.
b) Pressing
SYSTEM
SWITCH
to change operating
modes.
c) Pressing or , creating a call
for COOL too soon after a previous call.
SYSTEM INDICATOR LIGHTS — The red
indicator light comes on whenever the heat-
ing or cooling system is operating. The
yellow indicator light comes on when the
second stage of heating or cooling is oper-
ating.
TOTAL KEYPAD LOCKOUT — When
option switch #4 is in the total keypad
lockout position (ON), programs cannot be
altered and all buttons are disabled.
Programming should be completed and bat-
tery should be installed before changing option
switch #4.
TOTAL KEYPAD LOCKOUT (ON)
Switch #1 set at installation (DO NOT CHANGE)
Switch #2 set at installation (DO NOT CHANGE)
Switch #3 (see EMR)
Switch #4 ON
Switches #1 and #2 are set at installation
and should not be changed. To enable total
keypad lockout, move option switch #4 to
ON. To disable total keypad lockout, move
option switch #4 to OFF.
NOTE
ON
1234